Immediate repair · Heat exchanger cover - Refurbishment
Heat Exchanger Cover Repair and Coating
Restore corroded heat exchanger covers and sealing surfaces with Super Metal Filler and Super Guard, 200 µm DFT per coat. Step-by-step procedure.

Step by step
Remove and inspect the cover. Surface preparation acc. to SepcoTech standards - abrasive blasting is recommended.
Rebuild deep damage with SepcoTech Super Metal Filler. Minor pitting can be levelled with Super Guard with the cover positioned horizontally.
Apply Release Agent to a flat reference plate and press it against the uncured material on the sealing face. Allow curing, remove the plate and finish by machining.
Apply a stripe coat of SepcoTech Super Guard to edges, corners and welds, followed by the first full coat - 200 µm DFT. Keep gasket faces uncoated.
Allow semi-curing.
Apply a second stripe coat and the second full coat of Super Guard - 200 µm DFT (400 µm in total).
Allow final curing. Inspect, reassemble with a new gasket and pressure test. Restore corroded heat exchanger covers, rebuild damaged sealing surfaces and protect them against corrosion.
Products used
Get in touch
Describe the damage. We'll specify the repair.
Tell us the dimensions, whether the surface is wet or dry, and the operating temperature and pressure. We normally reply within one business day.