Docking repair · Rudder stock bushing - Cast to fit
Rudder Stock Bushing: Epoxy Cast-to-Fit Method
Installation of a new or replacement rudder stock bushing using the SepcoTech Cast-to-Fit method. All mechanical work follows normal mechanical procedures and vessel requirements.


Step by step
Surface preparation acc. to SepcoTech standards. Surfaces must be clean, sound and roughened - blasting is preferred.
Ensure a continuous casting gap of min. approx. 3 mm between bushing and rudder trunk.
Make injection points at the bottom (e.g. M10) and venting points at the top.
Position, align and secure the bushing. Apply Release Agent to any temporary bolts or fixtures.
Verify alignment before casting - the casting material does not correct alignment.
Seal the lower edge between bushing and rudder trunk.
Fit the static mixing nozzle to the cartridge and dispense a little material until evenly mixed.
Inject slowly from the lowest point and work upwards, one injection point at a time. Avoid excessive pressure.
Stop when material appears at the top venting points, then close the holes with threaded bolts.
Allow full curing - do not disturb or load the bushing.
Remove temporary bolts, fixtures and excess material. Close all holes with SepcoTech repair material.
Final inspection of alignment, tolerances, clearances and complete filling.
Get in touch
Describe the damage. We'll specify the repair.
Tell us the dimensions, whether the surface is wet or dry, and the operating temperature and pressure. We normally reply within one business day.