Step by step
Inspect the casing. Surface preparation acc. to SepcoTech standards - abrasive blasting recommended.
Rebuild pits and eroded areas using SepcoTech Super Metal Filler. Use a temporary mould with SepcoTech Release Agent where the cover profile is lost.
Allow curing and restore the original geometry by sanding or machining.
Apply a stripe coat of SepcoTech Super Guard to welds, edges and transitions, followed by the first full coat - 200 µm DFT.
Allow semi-curing.
Apply a second stripe coat and the second full coat of Super Guard - 200 µm DFT.
Allow final curing, inspect the coating, then reassemble and test. Rebuild corroded and eroded bow thruster casing surfaces to their original geometry and protect them against corrosion.