Leaking, badly corroded pipes inside the ballast tanks of a container vessel. Sealed and rebuilt by the crew, in three steps, with no hot work and no downtime.
Prefer to talk? Call (+45) 6916 2400 or email tech@sepcotech.com
Before
After

Clean with Bio Cleaner, then take the pipe back to bare steel with mechanical tools and a rotating blaster disc.
Bio Cleaner #10254
Rotating Blaster Duo #10267
Brush on Super Guard and wrap Super Wrap Reinforcement Tape into the wet coat. It contains the leaks and reinforces the corroded pipe.

Overcoat all repaired areas with Super Guard for long-term protection against corrosion, erosion and impingement.
Leak sealingHigh-strength reinforcement for corroded or damaged pipes. Seals active leaks, also under water, and cures fast.
Small #10251Large #10252Product page
Coating and overcoat100% solids epoxy coating. Long-term protection against corrosion, erosion and impingement.
265 ml#10233Product page Brochure PDFThis case as a four-page PDF, ready to print or forward to the technical superintendent.
Before
AfterSupertankerCracked GRE pipes and a displaced coupling, bonded and sealed inside the ballast tanks.
See the repair
Before
AfterSteel and GRE pipesBlasted, then rebuilt with four coats of Super Guard and three layers of Super Wrap.
See the repair
Before
AfterSea chestCleaned with fresh water and coated straight away, back in service three days later.
See the repair
Before
AfterShipyardDeep pitting rebuilt with Super Metal Filler and accepted by the attending ABS surveyor.
See the repairTell us the dimensions, whether the surface is wet or dry, and the operating temperature and pressure. We normally reply within one business day.
No obligation. If another approach suits the damage better, we will say so.