Protect the hull around the scrubber overboard outlet from aggressive wash water with Super Guard, approx. 400 µm DFT in total. Step-by-step guide.
Prefer to talk? Call (+45) 6916 2400 or email tech@sepcotech.com
Ordering through ShipServ? Find us under TNID 317548
Protection area & surface preparationFrom the outlet geometry and discharge direction, to SepcoTech standards PDF
Super Metal Filler CompoundRebuilds corroded or pitted areas, where required · #10240 PDF
Super Guard stripe coatsOutlet-to-hull transition, welds and edges, before each full coat PDF
Super Guard, two full coats200 µm DFT each, total approx. 400 µm DFT · #10233 / #10234 PDF
Alternatively, Aqua Guard can be used in the same sequence: 200 µm DFT per coat, applied by brush, roller or spray (#10238 / #10302).
The hull area around the scrubber outlet is exposed to aggressive scrubber wash water. This is the procedure from the SepcoTech epoxy instruction handbook.
Define the protection area around the outlet, according to outlet geometry and discharge direction. Surface preparation acc. to SepcoTech standards over the complete area.
Rebuild corroded or pitted areas using SepcoTech Super Metal Filler, where required.
Allow semi-curing.
Apply a stripe coat of SepcoTech Super Guard to the outlet-to-hull transition, welds and edges, followed by the first full coat: 200 µm DFT.
Allow semi-curing.
Apply a second stripe coat and the second full coat of SepcoTech Super Guard: 200 µm DFT (total approx. 400 µm DFT).
Allow final curing.
Note: brush application of Super Guard is recommended. Alternatively, SepcoTech Aqua Guard can be used in the same sequence: 200 µm DFT per coat, applied by brush, roller or spray.
Download this procedure as a PDF, or open the full instruction handbook. See also the case report: hull pitting.
Stripe coats and two full coatsTwo full coats of 200 µm DFT, total approx. 400 µm, with stripe coats on the outlet-to-hull transition, welds and edges. Brush application recommended.
265 ml#10233#10234Product page Brochure PDFWe have no published scrubber case yet. These repairs used the same SepcoTech products and the same steps you would use on a hull around the scrubber outlet.
The hull area around the scrubber outlet is exposed to aggressive scrubber wash water, which drives faster corrosion than on the rest of the hull. See all scrubber epoxy solutions.
Two full coats of SepcoTech Super Guard at 200 µm DFT each, total approx. 400 µm DFT, with stripe coats on the outlet-to-hull transition, welds and edges.
Brush application of Super Guard is recommended.
Yes. SepcoTech Aqua Guard can be used in the same sequence, 200 µm DFT per coat, applied by brush, roller or spray.
Tell us the dimensions, whether the surface is wet or dry, and the operating temperature and pressure. We normally reply within one business day.
No obligation. If another approach suits the damage better, we will say so.