Scrubber & GRE · Overboard hull protection

Scrubber outlet hull protection coating.

Protect the hull around the scrubber overboard outlet from aggressive wash water with Super Guard, approx. 400 µm DFT in total. Step-by-step guide.

Prefer to talk? Call (+45) 6916 2400 or email tech@sepcotech.com

Ordering through ShipServ? Find us under TNID 317548

  • Scrubber wash water systems, GRE and steel
  • Super Guard, two coats of 200 µm DFT, approx. 400 µm in total
  • Aqua Guard in the same sequence by brush, roller or spray
  • ABS Product Design Assessment certificate on all products
Hull plate around a scrubber overboard outlet, seen from outside: 1 protection area defined and prepared, 2 pits rebuilt with Super Metal Filler, 3 stripe coat on the outlet-to-hull transition and welds, 4 two coats of Super Guard, approx. 400 µm DFT HULL SIDE, SEEN FROM OUTSIDE WL OUTLET 1 2 3 4
  1. 1Protection area & surface preparationFrom the outlet geometry and discharge direction, to SepcoTech standards PDF
  2. 2Super Metal Filler CompoundRebuilds corroded or pitted areas, where required · #10240 PDF
  3. 3Super Guard stripe coatsOutlet-to-hull transition, welds and edges, before each full coat PDF
  4. 4Super Guard, two full coats200 µm DFT each, total approx. 400 µm DFT · #10233 / #10234 PDF

Alternatively, Aqua Guard can be used in the same sequence: 200 µm DFT per coat, applied by brush, roller or spray (#10238 / #10302).

Coating
Super Guard
Total thickness
Approx. 400 µm DFT
Coats
2 × 200 µm + stripe coats
Pitted areas
Super Metal Filler
Alternative
Aqua Guard, brush, roller or spray
Surface prep
SepcoTech standards (guide)
Step by step

Protection of the hull area around the scrubber outlet.

The hull area around the scrubber outlet is exposed to aggressive scrubber wash water. This is the procedure from the SepcoTech epoxy instruction handbook.

  1. Define the area and prepare the surface

    Define the protection area around the outlet, according to outlet geometry and discharge direction. Surface preparation acc. to SepcoTech standards over the complete area.

  2. Rebuild pits

    Rebuild corroded or pitted areas using SepcoTech Super Metal Filler, where required.

  3. Semi-cure

    Allow semi-curing.

  4. Stripe coat and first coat

    Apply a stripe coat of SepcoTech Super Guard to the outlet-to-hull transition, welds and edges, followed by the first full coat: 200 µm DFT.

  5. Semi-cure

    Allow semi-curing.

  6. Second stripe coat and second coat

    Apply a second stripe coat and the second full coat of SepcoTech Super Guard: 200 µm DFT (total approx. 400 µm DFT).

  7. Final cure

    Allow final curing.

Note: brush application of Super Guard is recommended. Alternatively, SepcoTech Aqua Guard can be used in the same sequence: 200 µm DFT per coat, applied by brush, roller or spray.

Step-by-step illustration: Overboard Hull protection
Illustrations from the SepcoTech epoxy instruction handbook. Includes AI generated images.

Full procedure with photos

Download this procedure as a PDF, or open the full instruction handbook. See also the case report: hull pitting.

Download this procedure (PDF)
Proven on board

The same products and method, already proven at sea.

We have no published scrubber case yet. These repairs used the same SepcoTech products and the same steps you would use on a hull around the scrubber outlet.

FAQ

Hull protection around the scrubber outlet.

Why does the hull around a scrubber outlet need protection?

The hull area around the scrubber outlet is exposed to aggressive scrubber wash water, which drives faster corrosion than on the rest of the hull. See all scrubber epoxy solutions.

How thick is the hull protection coating?

Two full coats of SepcoTech Super Guard at 200 µm DFT each, total approx. 400 µm DFT, with stripe coats on the outlet-to-hull transition, welds and edges.

How should Super Guard be applied on the hull?

Brush application of Super Guard is recommended.

Is there an alternative to Super Guard?

Yes. SepcoTech Aqua Guard can be used in the same sequence, 200 µm DFT per coat, applied by brush, roller or spray.

Get in touch

Describe the damage.
We'll specify the repair.

Tell us the dimensions, whether the surface is wet or dry, and the operating temperature and pressure. We normally reply within one business day.

Request a quote or repair advice

No obligation. If another approach suits the damage better, we will say so.

Or email tech@sepcotech.com · Tel. (+45) 6916 2400

Call Get a quote in 1 day